Technical Specifications |
| |
|
|
|
|
|
| INSULATION RESISTANCE |
|
|
|
|
|
|
Display range Riso (Un ≥ 250V):
Display range Riso (Un ≤ 250V):
Resolution:
Accuracy:
Nominal test voltage:
Generator current capability:
Display range (test voltage): |
0 – 000 M to 29.9 GΩ
0 – 000 M to 199.9 MΩ
0.001, 0.01, 0.1, 1, 10, 100 MΩ
± 2 % + 2 digits …0 to 199.9 MΩ
50 to 1000 V in steps of 10 V
> 1 mA at Unom
0 to 1200 V |
|
|
|
| |
|
|
|
|
|
| CONTINUITY OF PROTECTION CONDUCTORS (single measurement) |
|
|
|
|
|
|
Display range:
Accuracy:
Test current:
Compensation of test leads (up to 5 Ω):
Automatic polarity exchange: |
0.00 to 19.99, 20.0 to 199.9, 200 to 1999 Ω
± 2 % + 2 digits … ± 3 %
> 200 mA
Yes
Yes |
|
|
|
|
| |
|
|
|
|
|
| CONTINUITY (continuous measurement) |
|
|
|
|
|
|
Display range:
Accuracy:
Short-circuit test current: |
0.0 to 199.9 Ω, 200 to 1999 Ω
± 3 % + 2 digits
< 7 mA |
|
|
|
|
| |
|
|
|
|
|
| EARTH RESISTANCE (four-lead method) |
|
|
|
|
|
|
Display range:
Resolution:
Basic accuracy:
Test voltage:
Short-circuit test current:
High noise rejection:
Automatic potential and current probe
resistance: |
0 to 19.9 kΩ
0.01, 0.1, 1, 10 Ω
± 2 % + 3 digits … 0 to 2 kΩ
< 40 V / 125 Hz / sine wave
< 20 mA
Yes
Yes |
|
|
|
| |
|
|
|
|
|
| EARTH RESISTANCE (four-lead method and clamp) |
|
|
|
|
|
|
Display range:
Other characteristics: |
0 to 1.99 kΩ
See four-lead method |
|
|
|
| |
|
|
|
|
|
| EARTH RESISTNACE (two test clamps) |
|
|
|
|
|
|
Display range:
Basic Accuracy: |
0 to 19.9 Ω, 20.0 to 100.0 Ω
± 10 % + 2 digits … ± 20 % |
|
|
|
| |
|
|
|
|
|
| SPECIFIC EARTH RESISTANCE |
|
|
|
|
|
|
Display range:
Calculation:
Distance between test rods:
Other characteristics: |
0 to 1999 kΩm
(kΩft.)
ρ = 2 π aRE
1 to 30 m (1 to 90 ft.)
See four-lead method |
|
|
| |
|
|
|
|
|
| VOLTAGE AC / DC |
|
|
|
|
|
|
Display range:
Accuracy:
Nominal frequency range: |
0 to 600 V
± 2 % + 2 digits
45 to 65 Hz, DC |
|
|
| |
|
|
|
|
|
| CURRENT (True RMS) – Options A1018 and A1019 |
|
|
|
|
|
|
Measurement principle:
Display Range:
Resolution:
Basic accuracy:
Nominal frequency: |
current clamp 1 A / 1 mA
0 to 200 A
0.1, 1 mA; 0.01, 0.1, 1 A
± 5 % + 5 digits … 0.5 mA to 200 A
50 / 60 Hz |
| |
|
|
|
|
|
| VARISTOR OVERVOLTAGE PROTECTION DEVICES – Breakdown voltage |
|
|
|
|
|
|
|
Measurement principle:
Display Range:
Accuracy:
Threshold current: |
DC voltage ramp (500 V/s)
50 to 1000 V
± 5 % + 10 V
1 mA |
|