Model MI 2092
Power Harmonics Analyzer
Description

The MI 2092 is a three-phase, multifunctional, portable power harmonics analyzer with six differential channels. This useful tool has the ability to measure, record, and analyze power distribution systems – including functions for power quality, measuring energy, and harmonics. The test set also comes with Power Link; a comprehensive, easy-to-use software program that makes it a snap to download, store, and analyze test information.

• Real-Time Scope and Meter Functions
• Measures Voltage, Current, and Power Flow
• Transient to 25 KHz
• Harmonic Analysis
• True Real-Time operation
• 2 Mega-byte of data storage
• Professional Recording functions
• Full meter / configuration menu access
• AC or Battery operation
• 3 Year warranty

Technical Specifications
 AC VOLTAGES
Three-phase AC voltage input (3 differential inputs, L1 - N1, L2 - N2, L3 - N3)
Input Voltage Range:


Optional on Request:

10-550 Vrms L-N, 900 Vrms L-L
600 Vrms L-N (over load 10 s)

10-750 Vrms L-N, 1000 Vrms L-L
800 Vrms L-N (overload 10 s)

Resolution:
Accuracy:
Crest Factor Max:
Frequency Range:
0.1 V
0.5% of reading 2 digits
1.4
43-68 Hz fundamental
 AC CURRENTS
Three-phase AC input for connection to current transducers with voltage output
Input current ( voltage range):

Resolution:

Accuracy:

Crest Factor:

Maximum permissible Overload:

Maximum Input Voltage:
0.02-1 Vrms (from 0.02 x ln to ln) input

0.3 mV (0.3 A with 1000 A / 1 V)

0.5% of reading 6 digits plus current transformer

2.5

150% ln (sinusoidal current)

1 Vrms
 PHASE ANGLE
Consider phase angle data of used current transformer.
 SCOPE
Display Options


Ranging
Waveform of pairs ( L1:U1 and l1 and L2: U2 and l2,
L3: U3 and 13), U1,2,3 and  l1,2,3

Auto / Manual
 METER - Power Measurement
Quantities related to selected measuring connections per phase, i.e.:
Measured:
Calculated:
voltage (U), current(l), cos between U and l
active power (P), apparent power(S), reactive power(Q),
power factor(Pf) with its characteristic (c,l, none)
Line - Line voltage;
Quantities for complete three-phase system, i.e.:
Calculated: active power (Pt), apparent power (St), reactive power
(Qt), power factor (Pft), neutral current (ln);
Basic Accuracy for P ,Q,S:
Resolution for P,Q,S:
Basic accuracy for P ,Q,S:
Resolution for P,Q,S:
active power (Pt), apparent power (St) reactive power
(Qt), power factor (Pft), neutral current(ln);
1% of reading
0.01 of displayed value
 SPECTRUM - Harmonics Measurement
The instrument computes harmonics on signals sampled with an A/D converter.
Recording Interval:
Spectrum Calculation Range:
Spectrum Display Range:
Display Items for Selected Harmonic:
160 ms ( cycles)
DC - 63rd
DC - 25th
Order, relative and absolute value
Range
Limits of Error
Resolution
l range  U range

2 ... 100%
THD Totla Harmonic
Distortion
0.2 % x Ur / U (Ir / l )
HD Harmonic
Distortion
0.2% xUr / U (l r / l )
on LCD and PC

01%
 ENERGY
Displayed quantities from integration of calculated power as:
 - Cumulative values (TOTAL);
 - Partly cumulative (resettable by user request) ( SUBTOTAL);
 - Values related to last integration period (LAST IP).

Quantities: Active energy (EP), capacitive energy (EQC), inductive energy (EQl)
Basic Accuracy:
Resolution:
1% of reading
0.1 of displayed value
 RECORDER

Periodics integration period:
Selected Signals:
Statistics Values:
Voltage Anomalies:

1 s - 900 s
max. 64
each period divided in 200 parts (0.1 ms)

based on half period, start, duration and extrems of voltage
 EN 50160 ANALYSIS MODE
Voltage dips, swells, sags and breaks, resolution 10 ms, no gaps
Voltage unsimetry, Voltage RMS values, Frequency
Harmonics:
Flickers Plt Pst:
up to 43rd component
no gap
 FLICKER MEASUREMENT
The instrument computes flickers according to IEC 61000-4-15
 WAVEFORMS
Sampling Rate:
Trigger:
Buffer:

Channels:

Pf, cos, Crest factor, THD U, I Frequency
Harmonics / Direction:
128 scans / period
level, manual, timer
min. 10 periods of pre / post size, up to 7812 periods can be recorded
3 x U, 3 X I, U lines, Min / Max rms values: Avg

magnitudes / positive / negative
 FAST LOGGING
Sampling Rate:
Trigger:
Buffer:
Channels:
128 scans / period, min, max, Avg recorder each halfperiod
level, manual, timer
pre / post size, up to 166 minutes of recording
3 x U, 3X l, Single or multi-channel mode
 TRANSIENTS
Capturing:
Trigger:
Buffer:

Channels:

>20 u transient detect ability
Level, slope, manual
min. 10 periods of pre / post size, up to 1000 periods can be recorded
3 x U, 3 X l, Single of multi-channel mode

 

General Specifications

DISPLAY

Graphic Liquid Crystal Display (GLCD) with LED backlight,160 x 116 dots resolution

 NON-VOLATILE MEMORY
2048 Kbytes SRAM, battery backed
 
 DIGITAL HARDWARE SPECIFICATIONS
A/D conversion: 14 bit with 128 samples per channel per period (43-68 Hz)
OUTPUTS
Communication Type:
Baud Rate:
Connector:
Communication Cable:
RS 232 serial interface, fully opto isolated
2400-57600 baud.
9 pin D-type.
Standard Type
 POWER SUPPLY
Operating Range:
Optional:

DC Power Supply:


Charger:
230 VAC + 10% - 20%, 45-65 Hz, 8 VA
115 VAC + 10% - 20%, 45-65 Hz, 8 VA

Internal 4 x 1.2 V NiCd or NiMh rechargeable IEC LR14
batteries provide full operation for up tp 5 hours

Internal built-in battery charger, charging time approx. 10 hours
  GENERAL

Working Temp Range:
Max. Humidity:
Pollution Degree:
Protection Classification:
Overvoltage Category:

Protection Degree:
Dimensions:
Weight (without accessories):

- 20 °C ... + 60°C
85% RH (0 to 40 °C)
2
ll - double insulation
Voltage inputs: CAT lll 600 V; optional CAT lV 600 V
AC power supply CAT lll 300 V
IP 44 (IP 54 on request)
4.3in. (110 mm)x 10.4in. (265mm)x 7.3in. (185mm)
4.4 lbs. (2kg)
Standard Accessories


• Instrument carry case, soft sided with shoulder strap
• Small soft sided carry case with shoulder strap
• Current clamps – 1000 A / 1 V, Qty. 3
• Voltage measurement cables – Red, Qty. 3, and Black, Qty. 4
• Test tips – Red, Qty. 3
• Alligator clips – Black, Qty. 4
• Power cord – 6 ft.
• Batteries – NiCd 1.2 V, Qty. 4
• RS-232 Cable
• Power Link PC Analysis and control software package (for Windows 95 / 98 and 2000)
• Operation manual
• Test Certificate


Optional Accessories
 
A1039


Clamp Adapter
A1069

  100A / 1V Mini Clamp
A1099
Flex Clamp
       
    SPECIFICATIONS ARE SUBJECT TO IMPROVEMENT AT ANY TIME.  
  Back to Metrel Products Page